Brass Check Valve | Type A

Definition and Application
This type of valve is used to prevent water returning to the wats supply network The operation of this valve is based on changes in water pressure on each side. It is possible that the returned water may contaminate the water in the urban network due to contamination and raises some health problems. Also, it is possible that hot water swing check valve does not function in the internal network equipment well and eventually, hot water enters the meter and eventually dysfunctions the said meter.
The place for used
It is installed inside the meter box and connection pannel after the meter before the gate valve.
Key points
At the time of installation, one should be care about the direction of flash itched on the meter. The valve should be installed horizontally on the ground.
Work Temperature and Pressure
Work Temperature: 2-35 Degrees Centigrade / Work Pressure: 10 Atmosphere (10pn)
SN
V-25322
Component Parts and Material | ||||
Part Name | Material | ASTM Standard | EN Standard | Symbol |
Body | Brass | ASTM B455/C38500 ASTM B455/C38000 | EN12164/CW614N EN12164/CW617N | CuZn39Pb3 CuZn38Pb2 |
Disk | ||||
Cover | ||||
Cover | ||||
Hinge pin |

Body Dimension | |||||
SizeInch | A(mm) | B(mm) | C(mm) | D(mm) | Gears per Inch |
½ | 50 | 41 | 13 | 19 | 14 |
¾ | 54 | 51 | 19 | 24 | 14 |
1 | 65 | 58 | 23 | 31 | 11 |